Data transfer from N9912A
Thanks, I was able to connect the PC to the FieldFox and, after transferring the data from the SD card to the internal memory, retrieve the .csv files Expand Post
Global web icon
keysight.com
https://community.keysight.com/s/question/0D52L000…
FieldFox and External USB Power Sensor Measurements
FieldFox N9950 user. I employ VBA to communicate and pull data from the N9950 FieldFox. I have found the external USB Power Sensor to provide erroneous values when you switch between the SA and USB modes of operation, with the internal SOURCE providing a CW signal.
Global web icon
keysight.com
https://community.keysight.com/s/question/0D52L000…
Semi inaccurate information on FieldFox docs about ... - Keysight
The Lan WiFi adapter acts as adding WiFi functionality to the FieldFox, it's only as big as a pack of cigarets and powered by the USB port of FieldFox. I am sure you can find smaller models so not very clumsy. In this setup, there are two DHCP servers, one facing the FieldFox Lan port and the other from the router.
Global web icon
keysight.com
https://community.keysight.com/forums/s/question/0…
View .png image screen directly in Fieldfox display
You cannot recall a .png file on FieldFox itself. But if the goal is to see the same picture as what is saved with a png file on the FieldFox unit, you can save an .sta file (Trace+State. So change the save type to Trace+State. When you recall an .sta state+trace file, it comes up automatically in Hold (Cont OFF) mode, versus sweep (Cont ON), so you can see the exact screen you saved. That ...
Global web icon
keysight.com
https://community.keysight.com/forums/s/question/0…
FieldFox Analog Demod Tune & Listen
I have an N9915A FieldFox Analyzer running the latest firmware (A.08.15). I use its spectrum analyzer function to monitor various local voice communications frequencies and use the analog demod tune & listen feature frequently. As it is now, in order to configure the FieldFox to monitor a new frequency, I need to change the spectrum analyzer center frequency and then change the tune & listen ...
Global web icon
keysight.com
https://community.keysight.com/s/question/0D52L000…
Could someone give me the identification strings of *Agilent* VNAs.
Could someone give me a sample of what it would look with with an Agilent VNA? Would for example "Agilent" be spelt as "AGILENT" or "Agilent"? I'm not going to bother trying to include USB controlled devices like my FieldFox which is on order.
Global web icon
keysight.com
https://community.keysight.com/s/question/0D52L000…
Cal. kit inside the fieldfox dont show in menus
At the moment i'm facing the same situation as theamberco: a custom CalKit was sent to the FieldFox and is listed in DataLink using "show files" but neither the new connector family nor the Kit itself show up in the Calibration menu on the FieldFox. Same problem with other CalKits in .xkt-Format as the 85033-SMA.xkt Dave listed above.
Global web icon
keysight.com
https://community.keysight.com/s/question/0D52L000…
How to access Cal Sets remotely using FieldFox N9923A
FieldFox (including N9923A) saves one network analyzer calset per saved state. This calset applies to NA type modes, including VVM and CAT modes. Therefore, the method for achieving what you want is to perform instrument setup (including frequencies) and calibration, then save the instrument state.
Global web icon
keysight.com
https://community.keysight.com/s/question/0D52L000…
HP8508a - community.keysight.com
For Fieldfox N9923A, i can just insert the 2 output ports from my DUTs to Port 1 and Port 2 of fieldfox and will display the phase and amplitude different between my 2 DUT? is there any diagram on how to measure phase tracking between 2 channel?
Global web icon
keysight.com
https://community.keysight.com/forums/s/question/0…
N9912A bug - There must be =2 cal kits of same connector.
I wish Agilent would pay me for finding FieldFox bugs - I would be a rich man. It would appear that there needs to be at least two calibration kits of the same connector type before any of the calibration kits of that connector type are shown in the menus.